ASTM E331 00 PDF

The ASTM E (Standard Test Method for Water Penetration of Exterior Windows, Skylights, Doors, and Curtain Walls by Uniform Static Air Pressure. Imison. John H. Waskow, P.E.. Architectural Testing, Inc. Test Method: ASTM E , Test Method for Water Penetration of Exterior Windows, Curtain Walls. Purchase your copy of ASTM E – 00() as a PDF download or hard copy directly from the official BSI Shop. All BSI British Standards.

Author: Grorr Vudosho
Country: Greece
Language: English (Spanish)
Genre: Technology
Published (Last): 10 December 2005
Pages: 36
PDF File Size: 12.25 Mb
ePub File Size: 18.39 Mb
ISBN: 698-8-38012-471-7
Downloads: 62076
Price: Free* [*Free Regsitration Required]
Uploader: Mauramar

Procedure B is a cyclic static air pressure difference. In service, the performance will also depend on the rigidity of supporting construction and on the resistance of components to deterioration by various causes, vibration, thermal expansion and contraction, etc. Read more about what our customers have to say Conducting the investigative testing to verify and extend hypotheses arrived at during the document review and inspection portions of the investigation using controlled and reproducible procedures.

The reviewing of project documents for the building. Referenced Documents purchase separately The documents listed below ast referenced within the subject standard but are not provided as part of the standard. Which would be referred to as quality assurance testing. This specification is for axtm assurance testing only. Failures during quality assurance new awtm testing can result in unnecessary delays that impact your bottom line.

Water Penetration Field Testing

It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. This specification is for quality assurance testing only of storefronts, curtain walls and sloped glazing systems and their installation. Astj values given in parentheses are mathematical conversions to inch-pound units that are provided for information only and are not considered standard.

The main objective of forensic water testing is to identify the leak paths through the simulation of the weather events that produced the reported leakage. Analyzing the data and establishing a cause and effect relationship between wall characteristics and the observed leakage.

  BERETTA 9000S MANUAL PDF

ASTM International – Standard References for ASTM E – 00()

00 Procedure A is a uniform static air pressure difference. These factors should be fully considered prior to specifying the test pressure difference to be used. This standard is utilized for either field quality assurance testing or forensic testing. This allows us to not only properly test fenestrations on new construction projects, but also pinpoint the cause of any test failures and provide accurate recommendations to achieve successful testing results.

If you are looking for a reputable second or third-party testing company to perform accurate professional testing, provide concise reports, and help you through the entire process, contact BDG today. In applying the results of tests by this test method, note that the performance of a wall or its components, or both, may be a function of proper installation and adjustment. It is difficult to simulate the identical complex wetting conditions that can be encountered in service, with large asfm water drops, increasing water drop impact pressures with asfm wind velocity, and lateral or upward moving air and water.

ASTM E331 – 00(2016)

The AAMA is the proper test method for field testing of storefronts, curtain walls and sloped glazing for air leakage resistance and water penetration resistance performance. This field water check method 3e31 not intended to test the rated or specified water performance representative of a wind driven rain event. The water spray system has nozzles spaced on a grid to deliver water so that the test specimen is wet uniformly, includingthose areas vulnerable to water penetration.

The air-pressure differences acting across a building 000 vary greatly. Building Diagnostics Group, Inc. SITC determines what procedure to utilize based on the laboratory testing results. BDG utilizes professional testing equipment that is calibrated to each specific testing standard for accurate results.

The testing pressure differential is usually determined by the testing specifier. We provide testing services throughout the United States from our headquarters located in Atlanta, GA.

ASTM E | Water Penetration Testing

The calibrated spray apparatus spray-rack system delivers water to the test specimen at a rate of 5. Specifically excluded from this field check method is the testing of operable components such as operable window and doors.

  DANIEL ESTULIN OCTOPUS PDF

This differs greatly from the AAMA and E313 field testing procedures that are intended for evaluating newly installed fenestration products or quality assurance testing.

Most generic specifications call for a minimum testing pressure of 6. The purpose of this voluntary guideline is to recreate leaks that are known to occur.

Link to Active This link will always route to satm current Active version of the standard. Historical Version s – view previous versions of standard. This test method does not identify unobservable liquid water which may penetrate into the test specimen. BDG has extensive knowledge of most building systems and specializes in forensic water intrusion investigations.

Our field consultants are properly trained and knowledgeable of all testing standards. ASTM E references the following documents: Specifically excluded from this specification are windows, glass doors and skylights. This standard is utilized for laboratory or interior mock up testing only.

The diagnostic field water check is utilized for installed storefronts, curtain walls and sloped glazing systems only. There are two different procedures listed for the test method. It can only be utilized prior to the issuance of the building occupancy permit and no later than six months after the installation of the fenestration product.

These systems shall be tested per the AAMA Water that penetrates the assembly, but does not result in a failure as defined herein, may have adverse effects on the performance 00 contained materials such as sealants and insulating or laminated glass.

The evaluation of the design concept to determine if any water resistance performance requirements were specified for the wall.

Some designs are more sensitive than others to this upward moving water. See our page for further information.

ASTM states that the field test may be made at the time the window, skylight, curtain wall or door assemblies are initially installed.