ACI Code Requirements for Environmental Engineering Concrete Structures and Commentary, An ACI Standard [ACI Committee] on Read ACI Code Requirements for Environmental Engineering Concrete Structures by American Concrete Institute (ACI) for free with a 30 day free trial. ACI deletes ADM from the Code, but allows ACI continues to redraft and reballot a Code ACI Concrete Protection for

Author: Yosho Zulkigore
Country: Botswana
Language: English (Spanish)
Genre: Automotive
Published (Last): 19 August 2013
Pages: 100
PDF File Size: 8.64 Mb
ePub File Size: 12.56 Mb
ISBN: 918-1-11399-940-7
Downloads: 28350
Price: Free* [*Free Regsitration Required]
Uploader: Bashicage

I deal with the more traditional ACI structures water and wastewater treatment vessels and I didn’t realize that stormwater detention now fell under that. The rapid fluctuations of the force Pi mean that the bending moments and 350–06 in the wall of a rectangular tank also vary rapidly the effect is not like a constant force acting on the wall.

/R Code Requirements for Environmental Engineering Concrete Structures and Commentary

This affects slabs on-grade or structural slabs as well as walls that detain storm water. Individuals interested in the activities of ACI are encouraged to become a member.

It could also be argued that for walls that are exposed in this locale, considering the limited 24 hour detention time available of the water in the tank to 3500-6 the concrete walls, and considering the fact that most of the major storms in this area that would highly charge the tanks do not coincide aco the time of extended freezing conditions, the freezing of the wall in a saturated state is highly unlikely. For circular tanks, first calculate the natural period of vibration of vertical liquid motion Tv Eq.

Among the subjects covered are: Basic seismic design parameters: The pressures and forces on a cylindrical tank are similar to, but not the same as, those acting on a rectangular tank. They clde ancillary structures for dams, spill-ways, and channels. The design procedures described in Chapter 4 recognize that the seismic analysis of liquid-containing structures subjected to a horizontal acceleration should include the 305-06 forces generated by the acceleration of the structure itself; and the hydrodynamic forces generated by the horizontal acceleration of the contained liquid.

In anchored, flexible-base, circular tanks Type 2. Engineering judgment may require a factor I greater than tabulated in Table 4. ACI gathers and distributes information on the improvement of design, construction and maintenance of concrete products and structures. The resulting hydrodynamic definition of seismic effects. Compute period of vibration Ti in accordance with Eq.

  ARROCES CONTEMPORANEOS PDF

Using the seismic zone determined in Step 1, find the zone factor Z from Table I; 3. For partially buried tanks, the Ri value may be linearly interpolated between that shown for acci on grade and for buried tanks.

Compute the vertical amplification factor Ct in accordance with Section 9. The resistance side of the seismic design, including load combinations and strength reduction factors, may be computed in accordance with the applicable provisions of UBC ICBO or ACIChapter 9; and 2.

Based on the natural periods determined in Step 10 and the design spectral response acceleration values derived in Step 2, calcu- late the corresponding seismic response coefficients Ci and Cc Eq. Where the approved standard defines acceptance criteria in terms of allowable stresses as opposed to strengthsthe design seismic forces obtained from this appendix shall be reduced by a factor of 1. Using the zone factor Z and the soil profile designation from Steps 2 and 3, find the seismic coefficient Ca from Table Q and seismic coefficient Cv from Table R; 5.

And I very seldom provide movement joints unless the structure is in the hundreds of feet. During an earthquake, the force Pi changes direction several times per second, corresponding to the change in direction of the base acceleration; the overturning moment generated by Pi is thus frequently ineffective in tending to clde the tank.

Where applicable, the lateral forces due to the dynamic earth and groundwater pressures against the buried portion of the walls shall be computed in accordance with the provisions of Chapter 8.

Normally psi was commonly used in the past for many of these tanks for the walls, and psi or so for the slabs — occasionally higher if need for strength.

Typical earthquake force distributions in walls of rectangular and circular tanks are presented in R5. The temperature reinforcing required used to be. The maximum reaction force will be given by 2. The 3550-06 and testing of materials used in the construction are covered codde reference to the appropriate standard specifications.

The sloshing pressures on the tank walls result from the fluid zci associated with the wave oscillation.

International Concrete Abstracts Portal

The quality and testing of materials used in the construction are covered by reference to the appropriate standard specifications. Using the values of Ca, Cv, and Ts, construct a design response spectrum as in Fig.

  LITSEA GLUTINOSA PDF

A plot of the seismic response coefficient Ci is shown in the design response spectrum in Fig.

Select an importance factor I from Table 4. Remember me on this computer. From the applicable seismic ground motion map of ASCEChapter 22, obtain the mapped maximum considered earth- quake spectral 3350-06 accelerations at short periods and at 1 second SS and S1, respectively.

Note that mass is equal to weight divided by the acceleration due to gravity. Where dowels are provided to transfer this shear, the distribution will 530-06 the same as shown in Fig. Sachdev Chair Jon B. So, to control the oils and chemicals, if we do not want to useshould we just employ a biofilter before the tank?

350M-06 Code Requirements for Environmental Engineering Concrete Structures & Commentary (Metric)

Are you an Engineering professional? This material may not be reproduced or copied, in whole or part, in any printed, mechanical, electronic, film, or other distribution and codde media, without the written consent of ACI.

For circular tanks, the vertical distribution of the impulsive and convective forces is identical to that shown above for rectangular tanks, while the horizontal distribution varies along the tank circumference as shown in Fig. Typical structures include cdoe, storage, and treatment structures. The profile of the response spectrum is defined by Sa, which is a function of the period of vibration and the mapped accelerations SS and S1 as described in Section R9.

Resources Digital Transformation may be defined in a number of different ways by analysts or enterprise software vendors. The roof-to-wall joint is subject to earthquake shear from the horizontal acceleration of the roof. ACI Committee Reports, Guides, Standards, and Commentaries are intended for guidance in planning, designing, executing, and inspecting construction.

The Institute shall not be liable for any loss or damage arising process, or by any electronic or mechanical device, printed or written therefrom. For a listing of and access to all product errata, visit the Errata page. The duration of the fluctuations is 10 to 15 seconds for earth- quakes of magnitude 6.